§ 7-85. Structure fill material.  


Latest version.
  • A. 
    Detrimental amounts of organic material shall not be permitted in fills. Except as permitted by the City engineer, no rock or similar irreducible material with a maximum dimension greater than twelve inches shall be buried or placed in fills.
    B. 
    Exception. The City engineer may permit placement of larger rock when the soils/civil engineer requesting such placement properly devises a method of placement, continuously inspects its placement, and approves the fill stability. The following conditions shall also apply:
    (1) 
    Potential rock disposal areas shall be delineated on the grading plan;
    (2) 
    Rock sizes greater than twelve inches in maximum dimension shall be ten feet or more below grade measured vertically;
    (3) 
    Rocks shall be placed so as to assure filling of all voids;
    (4) 
    All fills shall be compacted to a minimum of ninety percent of maximum density as determined by ASTM D-698-70 and ASHTO T99. Field density shall be determined in accordance with ASTM D-698-70 or the most recent update thereof, or equivalent as approved by the City engineer;
    (5) 
    The slope of fill surfaces shall be no steeper than is safe for the intended use. Fill slopes shall be no steeper than three horizontal to one vertical.